PVC Tubings
Material
Flexible, Flame retardant PVC
Feature
DEVELOP is a flame-retardant flexibie PVC tubing that is recognized by Underwriters Laboratories(UL) and Canadian standards Association(CSA), is a high-reliability products.
Marking
Following letters are prrinted on the tubing
UL DEV-300 VW-1 PVC 105C E152386 DEVELOP LR77177 CSA 105C NHS VW-1PVC DEV-300
UL DEV-300 VW-1 PVC 105C E152386 DEVELOP LR77177 CSA 105C NHS VW-1PVC DEV-300
SGS Report
Properties
Temperature rating | 20℃~105℃ | ||
---|---|---|---|
Item | UL | CSA | |
PHYSICAL | Tensile strength(unaged) | 10.4MP(1.05kg/mm2)min | 10.4MP(1.05kg/mm2)min |
strength(aged) | 136℃x7Days.70% of Origind min | 121℃x21Days.75% of Origind min | |
Elongation(unaged) | 100% min | 100% min | |
Elongation (aged) | 136℃x7days.70% of Originat min | 121℃x21days.100% min | |
Flexibility | 136℃x7days.no crack | - | |
Deformation | 121℃x1Hr.50% max | 131℃x1Hr.35% max | |
Heat shock | 121℃x1Hr.no crack | 131℃x14days.no crack | |
Cold bend | -10℃x1Hr.no crack | -30℃x1Hr.no crack | |
Longitudinat change | 100℃x2Hrs.±5% | 130℃x2Hrs.±10%max | |
ELECTRICAL | Dielectric voltage ithstond(unaged) | AC2.5KV 60sec.OK | AC2.5KV 60 sec. ok |
Dielectric voltage | 136℃x7days.AC2.5KV | 121℃x21Days | |
withstond(aged) | 60sec. | ||
voltage bteck down(unoged) | AC2.5KV min | AC2.5KV min | |
voltage bteck down(oged) | 136℃x7days.50%of original min | 121℃x21 Days.50%of original min | |
volume reststivity | 1010Ω.cm min | at 105℃ 3mΩ-m min | |
CHEMICAL | Corrosion of bare Copper | 136℃x7days.ok | 121℃x21days.ok |
Copper stability | 136℃x7days.70%of original min | 121℃x21days.no degradation | |
Flommability | vw-1 | VW-1 | |
oil resistivity | - | 70℃x4Hrs,more than 75% | |
varnish resistivity | - | no crack |
Pecognition UL CSA
ITEM | UL224 | CSA C22-2 |
---|---|---|
File NO | E152386 | LR77177 |
Voltage | 300V ond 600v | |
Temper lure | 105℃ | 105℃ |
Flommobilty | VW-1 of FR-1 | VW-1 |
DEVELOP
- DEV-300 300V,105℃, DEV-600 600V,105℃
- UL 224 FILE NO. E152368,CSA C22.2 FILE NO.LR77177
- USE: The tubing is intended for use in damp or dry locations to insulate bare live parts or supplement existing
insulation in electrical equipment
- Color: Clear/Black
Product Sizes
SIZE | Inside | Dev-300(300V,105℃) | Dev-600(600V,105℃) | ||||
---|---|---|---|---|---|---|---|
AWG | Diameter (m/m) |
Min.(mm) Thickness | Avg.(mm) Thickness | Outside Diameter | Min.(mm) Thickness | Avg.(mm) Thickness | Outside Diameter |
20 | 0.864 | 0.330 | 0.40 | 1.70 | 0.431 | 0.60 | 2.10 |
19 | 0.965 | 0.330 | 0.40 | 1.80 | 0.431 | 0.60 | 2.20 |
18 | 1.067 | 0.330 | 0.40 | 1.90 | 0.431 | 0.60 | 2.30 |
17 | 1.19 | 0.330 | 0.40 | 2.00 | 0.559 | 0.70 | 2.60 |
16 | 1.34 | 0.330 | 0.40 | 2.15 | 0.559 | 0.70 | 2.75 |
15 | 1.50 | 0.330 | 0.40 | 2.30 | 0.559 | 0.70 | 2.90 |
14 | 1.68 | 0.330 | 0.40 | 2.50 | 0.559 | 0.70 | 3.10 |
13 | 1.93 | 0.330 | 0.40 | 2.70 | 0.559 | 0.70 | 3.35 |
12 | 2.16 | 0.330 | 0.40 | 3.00 | 0.559 | 0.70 | 3.60 |
11 | 2.41 | 0.330 | 0.40 | 3.20 | 0.559 | 0.70 | 3.80 |
10 | 2.69 | 0.330 | 0.40 | 3.50 | 0.559 | 0.70 | 4.10 |
9 | 3.00 | 0.431 | 0.55 | 4.10 | 0.559 | 0.70 | 4.40 |
8 | 3.38 | 0.431 | 0.55 | 4.50 | 0.559 | 0.70 | 4.80 |
7 | 3.76 | 0.431 | 0.55 | 4.90 | 0.559 | 0.70 | 5.20 |
6 | 4.22 | 0.431 | 0.55 | 5.35 | 0.559 | 0.70 | 5.65 |
5 | 4.72 | 0.431 | 0.55 | 5.83 | 0.559 | 0.70 | 6.15 |
4 | 5.28 | 0.431 | 0.55 | 6.40 | 0.559 | 0.70 | 6.70 |
3 | 5.94 | 0.431 | 0.55 | 7.05 | 0.559 | 0.70 | 7.35 |
2 | 6.68 | 0.431 | 0.55 | 7.80 | 0.559 | 0.70 | 8.10 |
1 | 7.47 | 0.431 | 0.55 | 8.60 | 0.559 | 0.70 | 8.90 |
0 | 8.38 | 0.431 | 0.55 | 9.50 | 0.559 | 0.70 | 9.80 |
5/16" | 7.92 | 0.559 | 0.70 | 9.35 | 0.559 | 0.70 | 9.35 |
3/8" | 9.53 | 0.559 | 0.70 | 10.95 | 0.559 | 0.70 | 10.95 |
7/16" | 11.10 | 0.559 | 0.70 | 12.50 | 0.559 | 0.70 | 12.50 |
1/2" | 12.70 | 0.559 | 0.70 | 14.10 | 0.559 | 0.70 | 14.10 |
— | 14.29 | 0.559 | 0.70 | 15.69 | 0.559 | 0.70 | 15.69 |
— | 16.50 | 0.559 | 0.70 | 17.90 | 0.559 | 0.70 | 17.90 |
— | 19.50 | 0.559 | 0.70 | 21.90 | 0.559 | 0.70 | 21.90 |